INSTALLATION
MOUNT HEIGHTS
DUCTING
7-5/8"
36"
96"
Min 24"-Max 32"
Minimum mount height between range top to
hood bottom should be no less than 24".
Maximum mount height should be no higher
than 32".
It is important to install the hood at the
proper mounting height. Hoods mounted too
low could result in heat damage and fire haz-
ard; while hoods mounted too high will be
hard to reach and will loose its performance
and efficiency.
If available, also refer range manufacturer's
height clearance requirements and recom-
mended hood mounting height above range.
A minimum of 6" round or 3-1/4” x 10"rectangular
duct must be used to maintain maximum air flow
efficiency.
Always use rigid type metal ducts only.
Flexible ducts could restrict air flow by up to 50%.
Also use calculation (on right) to compute total
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size from 6" to 7 or 8". If a reducer
is used, install a long reducer instead of a pancake
reducer. Reduce duct size as far away from open-
ing as possible.
If turns or transitions are required:
Install as far away from opening and as far
apart, between 2, as possible.
Minimum Duct Size:
Round:
6" minimum
Rectangular:
3-1/4” x 10”
Duct Run Calculation:
Maximum run
6" or 3-1/4” x 10" duct
Deduct:
each 90 Elbow used
each 45 elbow used
each 6" to 3/14 x 10"
transition used
each 3/14 x 10" to 6"
each 3/14 x 10" to 6"
transition used
Side Wall Cap w/ damper
Roof Cap
100 FT
15 FT
9 FT
1 FT
5 FT
30 FT
30 FT
e.g.- 1 roof cap, 2x90 elbows, 1 x 45 elbow used:
=30' + 30' + 9' =69' used, 31' available for straight duct runs.
USE, CARE, AND INSTALLATION GUIDE
Read all Instructions before Installing and operating this appliance
MODELS: AK6500, AK6536, AK6542 Cyclone AK2500, AK2536 Hurricane
WARNING
Installation
The installation in this manual is intended for qualified installers, service technicians or persons
with similar qualified background. DO NOT attempt to install this appliance yourself. Injury could
result from installing the unit due to lack of appropriate electrical and technical background.
All electrical wiring must be properly installed, insulated and grounded. Overly accumulated
grease in old duct work should be cleaned out or duct work should be replaced if necessary to
avoid the possibility of a grease fire. Check all joints on duct work to insure proper connection
and all joints should be properly taped.
Operations
Read all instructions in this manual before operating the appliance. Save these instructions for
future reference.
Always leave safety grills and filters in place. Without these components, operating blowers
could catch on to hair, fingers and loose clothing.
NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into blowers.
NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch fire.
The risk of self combustion is higher when the oil has been used several times.
Cleaning
The saturation of greasy residue in the blower and filters may cause increased inflammability.
Keep unit clean and free of grease and residue build-up at all times to prevent possible fires.
Filters must be cleaned periodically and free from accumulation of cooking residue (see clean-
ing instructions inside). Old and worn filters must be replaced immediately. Do not operate blow-
ers when filters are removed. Never disassemble parts to clean without proper instructions.
Disassembly is recommended to be performed by qualified personnel only. Call our service cen-
ter for removal instructions.
The manufacturer declines all responsibility in the event of failure to observe the instruc-
tions given here for installation, maintenance and suitable use of the product. The manufac-
turer further declines all responsibility for injury due to negligence and the warranty of the
unit automatically expires due to improper maintenance.
IMPORTANT SAFETY NOTICE
* Please check for latest specification revisions before any custom work or cutouts.
Models: AK6500, AK6536, AK6542, AK2500, AK2536 Page 1
Seitenansicht 0
1 2 3 4 5 6 7

Inhaltsverzeichnis

Seite 1 - INSTALLATION

INSTALLATIONMOUNT HEIGHTSDUCTING7-5/8"36"96"Min 24"-Max 32"Minimum mount height between range top tohood bottom should be no

Seite 2

INSTALLATIONSPECIFICATIONS7-5/8"22-1/4"30" 36" 42" TOP VIEW9"1-1/8"1"6-5/8"Elec K.

Seite 3

INSTALLATIONMOUNTING THE RANGEHOOD1. This range hood is mounted under a kitchen cabinet unit.2. Select preferred duct location on rear or top of unit.

Seite 4

INSTALLATIONCONVERTIBLE OPTIONSModels: AK6500, AK6536, AK6542, AK2500, AK2536 Page 7INSTALLATIONCONVERTIBLE OPTIONSModels: AK6500, AK6536, AK6542, A

Seite 5 - CONTROLS & FEATURES

CLEANING AND MAINTENANCESELF CLEAN FEATURECONTROLS & FEATURESCONTROLS & FEATURES (Models AK2500, AK2536)IIIIII3 Speed Level IndicationDelay Of

Seite 6 - MAINTENANCE

WARRANTYOne Year Service Repair Warranty:For one year from date of original purchase, we will provide free of charge, service labor to repairany faile