Read all Instructions before Installing and operating this appliance
MODEL: AK2000,AK6000,AK9800
Important Safety Notice
Use, Care and Installation Guide
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS
FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions,
contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock panel
to prevent power from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials
and vapors. Take care when using cleaning agents or detergents.
Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking
and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b. Always turn hood ON when cooking at high heat or when flaming food
c. Clean ventilating fans frequentl
y
. Grease should not be allowed to accumulate
on fan or filter.
d. Use proper pan size. Always use cookware appropriate for the size of the surface
element.
e. Keep fan, filters and grease laden surfaces clean.
f. Use high setting on hood only when necessary.
g. Don’t leave hood unattended when cooking.
h. Always use cookware and utensils appropriate for the type of and amount of food
being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP
FIRE, OBSERVE THE FOLLOWING:
a. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then
turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b. NEVER PICK UP A FLAMING PAN – You may be burned.
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam
explosion will result.
Rev:0605 www.zephyronline.com
READ AND SAVE THESE INSTRUCTIONS
Seitenansicht 0
1 2 3 4 5 6 ... 20 21

Inhaltsverzeichnis

Seite 1 - Important Safety Notice

Read all Instructions before Installing and operating this appliance MODEL: AK2000,AK6000,AK9800 Important Safety NoticeUse, Care and Install

Seite 2

INSTALLATION8REQUIREMENTSACCESSORIESWARNINGInstallation of this product is intended for qualified installers, service technicians, or persons with sim

Seite 3 - PRODUCT OVERVIEW

INSTALLATION9MIN. 18” MAX 30”net widthDUCT OPENING CLEARANCESFrontRearFrontRearWallMinimum clearance above range should be no less than 18“ from the

Seite 4 - Controls Overview

INSTALLATION10STEP 1STEP 3STEP 5STEP 2STEP 4STEP 6 (also refer notes on pg. 16)1. Remove all contents from box2. Unscrew and remove bottom grease spla

Seite 5

INSTALLATION11STEP 7STEP 9 (also refer notes on pg. 16)STEP 11STEP 8STEP 10STEP 12 (also refer notes pg. 16)1. Lift hood to bottom of cabinet1. Suppor

Seite 6 - CONTROLS

INSTALLATION12STEP 13STEP 15STEP 17STEP 14STEP 16STEP 181. On Cyclone & Whirlwind models, be sure to pull both grease tubes over its opening. 1. T

Seite 7 - MAINTENANCE

INSTALLATION13CONVERTIBLE OPTIONS3-1/4 x 10“ Vertical Discharge1. Remove pre-mounted 6“ transition adaptor on duct opening. Leave attached gasket in

Seite 8

INSTALLATION143-1/4 x 10“ Rear Discharge4. At rear of range hood, remove all screws on pre-mounted rear rectangular cap and remove cap with gasket.6.

Seite 9

INSTALLATION153-1/4 x 10“ Rear DischargeOption 2: (for flush cabinet base)Mount rectangular transition piece at opening with gasket as shown.Mount rec

Seite 10 - INSTALLATION

INSTALLATION16INSTALLATION NOTESStep 6: A damper (not included) should be installed to prevent back-draft where needed. A damper might also be requir

Seite 11

TROUBLE SHOOTING171. Upon completion of installation, nothing works.2. Light is on but blowers are not turning at all or seems to be scraping on some

Seite 12

Important Safety NoticeRead and save these instructionsd. Use an extinguisher ONLY if: 1. You know you have a Class ABC extinguisher, and you

Seite 13

TROUBLE SHOOTING1811. Cooking fumes and smoke dissipates before it reaches the blower.Use a damper type sidewall cap.Reduce the number of elbows and l

Seite 14

www.zephyronline.comWarrantyOne Year Service Repair Warranty:For one year from date of original purchase, we will provide free of charge, service labo

Seite 15

PRODUCT OVERVIEWWHIRLWIND SERIESHURRICANE SERIESCYCLONE SERIES1Model number: AK2000, 2036, QuattroVent Air Curtain, Dual “Thrust-Fore" Self Clean

Seite 16

CONTROLSHURRICANE SERIES2Controls Overview1. Set Time2. Digital Display3. Set Hours4. Set Minutes5. Set Timed Delay Shut Off6. Light On-Off7. Left Blo

Seite 17

Blower ControlsYou can simultaneously turn On the light and both blowers on Hi speed by simply pressing "On/Off" once.During this time, you

Seite 18

CONTROLS4Setting Timer (Alarm)Press "hr" and "min" button to set desired timer countdown.Once timer is set, countdown will start i

Seite 19 - TROUBLE SHOOTING

MAINTENANCE5Self Clean FeatureAll Zephyr Range Hoods are filter-less and are designed with a self clean feature. The centrifugal blower system automa

Seite 20

Hurricane Series:Remove light shield by turning counter-clockwise.Clean in dishwasher under normal wash cycle.Whirlwind Series:Remove light shield by

Seite 21 - Warranty

MAINTENANCE7QuattroVent ChannelsThe QuattroVent Air-Curtain channels are adjoined to its two main blowers and share the same internal housing. No fur