INSTALLATION
14
3-1/4 x 10“ Rear Discharge
4. At rear of range hood, remove all screws on pre-
mounted rear rectangular cap and remove cap with
gasket.
6. Remove 2 arch blocks through top opening.
Option 1: (for recessed cabinet base)
Re-install originally pre-mounted round transition
piece at opening with gasket.
7. Mount Starting Collar (provided) at rear discharge
opening with gasket previously removed.
Cap opening with 6“ cap provided OR, use option 2 if
cabinet base is not recessed.
5. Remove top pre-mounted transition piece. Leave
attached gasket in its original place.
Seitenansicht 15